Heat Treatment Furnace
HTF-TM1 Tempering Furnace
Low-temperature precisely controlled tempering furnace for post-quench treatment.
Post-quench tempering requires accurate temperatures in the 150–700 °C range to achieve the correct balance of hardness and toughness. The HTF-TM1's forced-air recirculation achieves ±3 °C uniformity, while its twin-chamber design allows simultaneous processing of two hardness grades.
Technical Specifications
- Temperature Range100–700 °C
- Chamber Size800 × 600 × 600 mm (×2 chambers)
- Power30 kW total
- Temperature Uniformity±3 °C
- Fan SpeedVariable frequency drive
- ControlDual-zone PID
- Load Capacity300 kg per chamber
- SafetyOver-temperature cutout, door interlock
Key Features
- Twin chamber for two simultaneous temper cycles
- ±3 °C uniformity via high-volume recirculation
- VFD fan speed matched to load thermal mass
- Hardness-grade recipe library (50 presets)
- Washable stainless-steel inner liners